ArchyRWS architecture
Menu
Archy RWS architecture
Markdown is the sourceBackend considerations
Search Archy…

Search Archy

SAK MK-koppelvlakken — distilled rules (English)

CurrentRWS BEDRIJFSVERTROUWELIJKReview not recorded

The author presents this as the current position. It is not a record of approval.

Local drafting workspace

SAK MK-koppelvlakken — distilled rules (English)

Security/SAK/SAK - MK-koppelvlaken v1.1.distilled.en.md

Local draft — not saved or submitted. Download and use the Git/PR workflow. Changes stay in this page’s memory, never alter the published note, and are lost on reload. The .md download contains the narrative only; preserve the original frontmatter in Git. The preview is not publication validation.

Preview

Images and raw HTML are disabled. Preview links do not navigate. Markdown links are checked when the source is built, not here.

Published source loaded. No local changes.

View source & provenance

Classification: RWS BEDRIJFSVERTROUWELIJK.

Source: SAK - MK-koppelvlaken v1.1.pdf, version 1.1, 18 July 2025, status DEFINITIEF. The PDF's internal title uses the correct Dutch word MK-koppelvlakken; the local source filename intentionally retains the assignment basename spelling MK-koppelvlaken. Derived from the Docling Markdown, with the scope-table colors documented.

This is a non-authoritative English distillation. All § references identify sections of the source PDF. SAK KV A–C are source control groups. Dutch zone names are retained where exact matching matters. Condensed bullets do not create official requirement IDs. The issued source governs.

How to apply

  • Apply the relevant control only in the domains populated in §1.6 and according to its subject. Domain colors distinguish columns only; a blank white cell is not independently interpreted as “not applicable” or an exemption.
  • Preserve the central architecture boundary: MK networks must be capable of complete isolation; permitted connectivity runs through a dedicated Koppelvlakken zone. Management/maintenance interfaces and partner data interfaces are functionally and logically separated, and each MK network has its own interface so MK networks cannot connect to one another (§1).
  • External access is not automatically permitted. Where a use case permits it, use the prescribed controlled route. The source explicitly says some parts of an MK network may prohibit external access entirely (§1.1).
  • Treat the page-5 zoning illustration as architectural context, not as an additional permission matrix. It depicts Purdue zones, RWS security zones, conduit components, functional zones, firewalls, sensors, separate Koppelvlak components, IA DMZ, back end, Beheer, SOC, and NOC; connectivity authority remains in the written rules and governing zoning framework.
  • For a finding, cite SAK - MK-koppelvlaken v1.1.pdf — SAK KV <group>, §<section>, p. <page> while preserving the PDF's internal title where required by records practice.

Terms

  • MK: mission-critical. IA / IV: industrial automation / RWS business IT.
  • Koppelvlak / Koppelvlakken: the controlled interface facility/zone between differently classified zones; the source places these interfaces at Purdue layer 3.5 between RWS IV and IA/MK environments.
  • IA DMZ: the zone containing the secure remote-access landing platform and the first staging-storage environment.
  • Namespace: the dedicated logical traffic context described in §§2.2–2.3. Do not assume a vendor-specific namespace implementation.
  • BIV score: the source's classification score for confidentiality, integrity, and availability; this SAK does not define its scale.

Applicability index — source §1.6, PDF page 7

Only source-populated cells are listed.

Section Datacenter Network Application Workplace Cloud
§2.1 IA IA blank IA blank
§§2.2–2.3, 3.1–3.4, 4.1–4.2 blank IA blank blank blank
§§4.3–4.4 IA IA blank blank blank

The source table contains 11 rows, 15 populated cells, and 40 blank cells.

Cross-cutting MK-interface rules — §§1–1.4

When: enabling security services, external administration, or external data exchange involving an MK network.

  • Keep RWS MK networks/systems completely isolated from RWS IV networks and apply the RWS zoning model.
  • Preserve the ability of the technical components, control/administration, and 24x7 operational services to function while the MK network is completely isolated.
  • Prohibit direct connections to MK networks; route them through the Koppelvlakken zone.
  • Harden each interface and monitor/filter its network traffic.
  • Route external access through the RWS secure remote-access platform using directory services and accounts separated from IV.
  • Make the complete access path and all activities visible and traceable in security logging.
  • Use safe, approved protocols for every connection.
  • Enable patching and RWS SOC monitoring for MK systems where possible, without turning that qualification into an unconditional feasibility claim.
  • Separate development and test environments.
  • Security services in MK networks must not disrupt operational systems, and delivery of security traffic to the RWS SOC must not be interrupted (§1.1).

SAK KV A — Expose and isolate security services

§2.1 — Staging platform (PDF page 8)

When: suppliers or administrators need to transfer tools/files from outside into an MK network for maintenance.

  • Use a two-part staging environment: storage in the IA DMZ at Purdue layer 3.5, and a second environment in the Koppelvlak zone on the outside of the data diode.
  • Support the three stated use cases: supplier upload through secure file transfer; checking uploaded files for malicious content; and automated movement of clean files to staging in the Koppelvlak zone.
  • Use secure file transfer under the Network Security capability.
  • Log file transfers and antivirus scan results.
  • Use current malware-detection products from at least two different suppliers.
  • Verify integrity, for example by checksum comparison, through a separate channel.

§2.2 — MK-network traffic towards SOC (pages 8–9)

  • Store log/security data, where possible, on a security device rather than on an MK component. Examples are sensors, IDS, local log servers, and firewalls.
  • Connect security devices to the MK network and place them in a dedicated namespace.
  • Configure that namespace unidirectionally: permit traffic from MK-Netwerken to SOC and block return traffic.
  • Make the namespace part of the SOC zone and use it only to send security logs from security devices to SOC.
  • Size/localize collection and transmission so the log volume does not cause operational disruption, as required by the section's rationale; the source provides no numeric threshold.

§2.3 — Beheer traffic towards MK security devices (page 9)

  • Make MK security devices reachable only from the Beheer zone and only through the Koppelvlak zone.
  • Connect the security devices to the MK network and place them in a dedicated namespace.
  • Configure that namespace unidirectionally: permit traffic from Beheer to MK-Netwerken and block return traffic.
  • Make the namespace part of the Beheer zone and use it only to push configuration or policy updates to security devices.

SAK KV B — External administrative access to MK networks

§3.1 — Register remote-access security groups (page 10)

  • Establish the different employee/user types that need access, covering internal RWS personnel and external parties.
  • Determine which external parties have access, on an individual or network basis.
  • Register external parties and contract relationships, recording: party name, contact, individual, contract number, contract owner, and—when there is a network connection—a reference to the ITSM tool.
  • Check the registration for currency monthly.
  • Use SAK Identity & Access Management for employee types, identities, and access groups.

§3.2 — Secure remote-access landing platform (page 10)

  • Terminate external connections on an RWS-managed VPN environment in the IA DMZ.
  • Whitelist where possible, for example by supplier network ranges.
  • Use user accounts and access roles managed in a directory service separated from IV directory services.
  • Apply conditional-access policies, including source and time as examples.
  • Monitor and log access.
  • Enforce MFA with at least two factors.
  • Allow RWS to enable/open an account through conditional access for maintenance or incident work.

§3.3 — Multifactor authentication (page 11)

  • Require every external access to RWS systems/infrastructure to use a personal account and password plus MFA.
  • For external administrative access to MK networks, use a separate user account as the first step when signing in to the RWS secure remote-access landing platform.
  • Enforce at least two factors.
  • Maintain compatibility with existing RWS identity providers/access-management systems, such as Azure AD and ADFS.
  • Support diverse factors, including TOTP, SMS, push notifications, biometrics, and hardware tokens. The source states capability support; it does not require all factors in every authentication event.
  • Provide a central console to define/manage policies, roles, users, and devices.
  • Provide high availability, reliability, and security, and comply with legal and organizational privacy/data-protection standards.
  • Scale and adapt to user counts, use-case diversity, and evolving threats.

§3.4 — MK access monitoring (page 11)

  • Log the whole route from initial sign-in at the secure remote-access landing platform to the administered MK component.
  • Record standard information such as username and source IP, plus successful and unsuccessful actions.
  • Correlate the different log sources so the full path leading to internal administrative access is visible in the Security Monitoring use case Externe toegang MK.

SAK KV C — External data connections for MK networks

§4.1 — Register data connections (page 12)

  • Route external data connections through RWS-provided and managed APIs.
  • Initially register and then maintain every active data connection, recording purpose, technical contact, business contact, connection/API type, and BIV score.
  • Check the registered information at least annually.

§4.2 — Data-connections register (page 12)

  • Maintain a structured overview of connections within RWS or between RWS and other organizations.
  • For each connection, record purpose, technical contact, business contact, connection/API type, and BIV score.
  • Check the registered information at least annually.

The source repeats the same five fields and annual-review requirement in §§4.1 and 4.2; this distillation retains both control locations rather than treating one as superseded.

§4.3 — API integration platform (pages 12–13)

  • Provide external API connections through the RWS integration platform/API Gateway in the IA DMZ, and make APIs/connections conform to RWS API-security requirements (§4.4).
  • Enforce RWS standardization for existing and new APIs.
  • Use pre-built connectors where possible.
  • Monitor use and enforce secure exposure through the API Gateway.
  • Support version management, an overview of the entire API landscape, and the complete API lifecycle.

§4.4 — Secure API guidelines / best practices (page 13)

  • Make RWS-provided and newly developed APIs comply with RWS Secure API / Secure Software Development policy, and continuously update that policy for innovation and new threats.
  • Publish APIs technically only through the RWS integration platform and enforce API-Gateway use for every API.
  • Use proven authentication mechanisms and protect the security and integrity of every access token.
  • Follow best practices for internal and external use. The source gives JSON Web Tokens with the parenthetical “internal only”; preserve that restriction/example without generalizing it beyond the wording.
  • Apply encryption under SAK Cryptografie Management.

Dependencies and source limitations

Dependency Use for
Identity & Access Management Identities/access through interface layers
Security Monitoring End-to-end access logging, SOC use cases
Cryptografie Management Encryption and cryptographic controls
Isolatie / Network Security Technical embedding, data diode, secure file transfer
Disaster Recovery Emergency scenarios
Vulnerability Management / Content Security Management Security-device functions and content scanning
RWS zoning, network architecture, CSIR, MK policy Zone assignments and detailed architecture
  • Coverage: substantive source §§1–4.4, all 11 controls, the full §1.6 table, and the page-5 architecture illustration's material legend/context. Cover, colophon, version history, contents, and decorative capability diagrams are omitted.
  • The scope table's 11 rows, 15 populated cells, 40 blanks, headers, orientation, and domain colors were visually checked against PDF page 7. The blank cells remain uninterpreted.
  • Material source defects/ambiguities: §1.1 says there are four goals but visibly presents only three; §§4.1 and 4.2 duplicate their fields/review interval; §2.3's unidirectional Beheer-to-MK rule blocks return traffic even though the rationale uses “reachable,” so do not invent a bidirectional exception; the source provides no availability/scale thresholds; and the JWT “internal only” wording in §4.4 is terse.
  • Original input Markdown SHA-256, before the transcription note: 7e1885eb1c60308ecbbf2b1cf49db2e4cd1ca3eaa75afbebacbba5fb14c842d5.
  • Source PDF SHA-256: 6d293de038d562f996fb08be68540267cb26dcdf3d2001516c2ab350d691afc5.
Explore this note’s relationships 2 connected notes

Connections are authored references and declared relationships, not verified runtime dependencies or approval.

3 notes · 2 relationships

Every note and relationship is available in the list below. The interactive map requires JavaScript.

Outline is the note kindABBSBBHLDResearchNoteMarkdown referenceTyped relationship
Icon is the documented subjectGeneral note
Notes and relationships Accessible list

Notes (3)

Relationships (2)

Source & provenance

This is the published reading view. The Markdown source and Git review workflow remain authoritative; publication is not architectural approval.

Source
Security/SAK/SAK - MK-koppelvlaken v1.1.distilled.en.md
Kind
Note
Status
Current, as authored
Classification
RWS BEDRIJFSVERTROUWELIJK
Revision
a3203210221340f80866b0462f4d63b49ebc5aea

Review not recorded. A recorded review date is the author’s review of the whole note, not an edit date, build date or approval. Editing a local draft does not update it.

Read the Markdown source

Read-only narrative source. Authored labels and relationships are listed above; this view does not write to the vault.


# SAK MK-koppelvlakken — distilled rules (English)

**Classification: RWS BEDRIJFSVERTROUWELIJK.**

**Source:** SAK - MK-koppelvlaken v1.1.pdf, version 1.1, 18 July 2025, status DEFINITIEF. The PDF's internal title uses the correct Dutch word **MK-koppelvlakken**; the local source filename intentionally retains the assignment basename spelling **MK-koppelvlaken**. Derived from [the Docling Markdown, with the scope-table colors documented](SAK%20-%20MK-koppelvlaken%20v1.1.md).

This is a non-authoritative English distillation. All `§` references identify sections of the source PDF. `SAK KV A–C` are source control groups. Dutch zone names are retained where exact matching matters. Condensed bullets do not create official requirement IDs. The issued source governs.

## How to apply

- Apply the relevant control only in the domains populated in §1.6 and according to its subject. Domain colors distinguish columns only; a blank white cell is not independently interpreted as “not applicable” or an exemption.
- Preserve the central architecture boundary: MK networks must be capable of complete isolation; permitted connectivity runs through a dedicated `Koppelvlakken` zone. Management/maintenance interfaces and partner data interfaces are functionally and logically separated, and each MK network has its own interface so MK networks cannot connect to one another (§1).
- External access is not automatically permitted. Where a use case permits it, use the prescribed controlled route. The source explicitly says some parts of an MK network may prohibit external access entirely (§1.1).
- Treat the page-5 zoning illustration as architectural context, not as an additional permission matrix. It depicts Purdue zones, RWS security zones, conduit components, functional zones, firewalls, sensors, separate Koppelvlak components, IA DMZ, back end, Beheer, SOC, and NOC; connectivity authority remains in the written rules and governing zoning framework.
- For a finding, cite `SAK - MK-koppelvlaken v1.1.pdf — SAK KV <group>, §<section>, p. <page>` while preserving the PDF's internal title where required by records practice.

### Terms

- **MK:** mission-critical. **IA / IV:** industrial automation / RWS business IT.
- **Koppelvlak / Koppelvlakken:** the controlled interface facility/zone between differently classified zones; the source places these interfaces at Purdue layer 3.5 between RWS IV and IA/MK environments.
- **IA DMZ:** the zone containing the secure remote-access landing platform and the first staging-storage environment.
- **Namespace:** the dedicated logical traffic context described in §§2.2–2.3. Do not assume a vendor-specific namespace implementation.
- **BIV score:** the source's classification score for confidentiality, integrity, and availability; this SAK does not define its scale.

### Applicability index — source §1.6, PDF page 7

Only source-populated cells are listed.

| Section | Datacenter | Network | Application | Workplace | Cloud |
|---|---|---|---|---|---|
| §2.1 | IA | IA | blank | IA | blank |
| §§2.2–2.3, 3.1–3.4, 4.1–4.2 | blank | IA | blank | blank | blank |
| §§4.3–4.4 | IA | IA | blank | blank | blank |

The source table contains 11 rows, 15 populated cells, and 40 blank cells.

## Cross-cutting MK-interface rules — §§1–1.4

**When:** enabling security services, external administration, or external data exchange involving an MK network.

- Keep RWS MK networks/systems completely isolated from RWS IV networks and apply the RWS zoning model.
- Preserve the ability of the technical components, control/administration, and 24x7 operational services to function while the MK network is completely isolated.
- Prohibit direct connections to MK networks; route them through the `Koppelvlakken` zone.
- Harden each interface and monitor/filter its network traffic.
- Route external access through the RWS secure remote-access platform using directory services and accounts separated from IV.
- Make the complete access path and all activities visible and traceable in security logging.
- Use safe, approved protocols for every connection.
- Enable patching and RWS SOC monitoring for MK systems **where possible**, without turning that qualification into an unconditional feasibility claim.
- Separate development and test environments.
- Security services in MK networks must not disrupt operational systems, and delivery of security traffic to the RWS SOC must not be interrupted (§1.1).

## SAK KV A — Expose and isolate security services

### §2.1 — Staging platform (PDF page 8)

**When:** suppliers or administrators need to transfer tools/files from outside into an MK network for maintenance.

- Use a two-part staging environment: storage in the IA DMZ at Purdue layer 3.5, and a second environment in the `Koppelvlak` zone on the outside of the data diode.
- Support the three stated use cases: supplier upload through secure file transfer; checking uploaded files for malicious content; and automated movement of clean files to staging in the `Koppelvlak` zone.
- Use secure file transfer under the Network Security capability.
- Log file transfers and antivirus scan results.
- Use current malware-detection products from **at least two different suppliers**.
- Verify integrity, for example by checksum comparison, through a **separate channel**.

### §2.2 — MK-network traffic towards SOC (pages 8–9)

- Store log/security data, where possible, on a security device rather than on an MK component. Examples are sensors, IDS, local log servers, and firewalls.
- Connect security devices to the MK network and place them in a dedicated namespace.
- Configure that namespace unidirectionally: permit traffic from `MK-Netwerken` to `SOC` and block return traffic.
- Make the namespace part of the `SOC` zone and use it only to send security logs from security devices to SOC.
- Size/localize collection and transmission so the log volume does not cause operational disruption, as required by the section's rationale; the source provides no numeric threshold.

### §2.3 — Beheer traffic towards MK security devices (page 9)

- Make MK security devices reachable only from the `Beheer` zone and only through the `Koppelvlak` zone.
- Connect the security devices to the MK network and place them in a dedicated namespace.
- Configure that namespace unidirectionally: permit traffic from `Beheer` to `MK-Netwerken` and block return traffic.
- Make the namespace part of the `Beheer` zone and use it only to push configuration or policy updates to security devices.

## SAK KV B — External administrative access to MK networks

### §3.1 — Register remote-access security groups (page 10)

- Establish the different employee/user types that need access, covering internal RWS personnel and external parties.
- Determine which external parties have access, on an individual or network basis.
- Register external parties and contract relationships, recording: party name, contact, individual, contract number, contract owner, and—when there is a network connection—a reference to the ITSM tool.
- Check the registration for currency **monthly**.
- Use SAK Identity & Access Management for employee types, identities, and access groups.

### §3.2 — Secure remote-access landing platform (page 10)

- Terminate external connections on an RWS-managed VPN environment in the `IA DMZ`.
- Whitelist where possible, for example by supplier network ranges.
- Use user accounts and access roles managed in a directory service separated from IV directory services.
- Apply conditional-access policies, including source and time as examples.
- Monitor and log access.
- Enforce MFA with at least **two factors**.
- Allow RWS to enable/open an account through conditional access for maintenance or incident work.

### §3.3 — Multifactor authentication (page 11)

- Require every external access to RWS systems/infrastructure to use a personal account and password plus MFA.
- For external administrative access to MK networks, use a separate user account as the first step when signing in to the RWS secure remote-access landing platform.
- Enforce at least two factors.
- Maintain compatibility with existing RWS identity providers/access-management systems, such as Azure AD and ADFS.
- Support diverse factors, including TOTP, SMS, push notifications, biometrics, and hardware tokens. The source states capability support; it does not require all factors in every authentication event.
- Provide a central console to define/manage policies, roles, users, and devices.
- Provide high availability, reliability, and security, and comply with legal and organizational privacy/data-protection standards.
- Scale and adapt to user counts, use-case diversity, and evolving threats.

### §3.4 — MK access monitoring (page 11)

- Log the whole route from initial sign-in at the secure remote-access landing platform to the administered MK component.
- Record standard information such as username and source IP, plus successful and unsuccessful actions.
- Correlate the different log sources so the full path leading to internal administrative access is visible in the Security Monitoring use case `Externe toegang MK`.

## SAK KV C — External data connections for MK networks

### §4.1 — Register data connections (page 12)

- Route external data connections through RWS-provided and managed APIs.
- Initially register and then maintain every active data connection, recording purpose, technical contact, business contact, connection/API type, and BIV score.
- Check the registered information **at least annually**.

### §4.2 — Data-connections register (page 12)

- Maintain a structured overview of connections within RWS or between RWS and other organizations.
- For each connection, record purpose, technical contact, business contact, connection/API type, and BIV score.
- Check the registered information **at least annually**.

The source repeats the same five fields and annual-review requirement in §§4.1 and 4.2; this distillation retains both control locations rather than treating one as superseded.

### §4.3 — API integration platform (pages 12–13)

- Provide external API connections through the RWS integration platform/API Gateway in the `IA DMZ`, and make APIs/connections conform to RWS API-security requirements (§4.4).
- Enforce RWS standardization for existing and new APIs.
- Use pre-built connectors **where possible**.
- Monitor use and enforce secure exposure through the API Gateway.
- Support version management, an overview of the entire API landscape, and the complete API lifecycle.

### §4.4 — Secure API guidelines / best practices (page 13)

- Make RWS-provided and newly developed APIs comply with RWS Secure API / Secure Software Development policy, and continuously update that policy for innovation and new threats.
- Publish APIs technically **only** through the RWS integration platform and enforce API-Gateway use for every API.
- Use proven authentication mechanisms and protect the security and integrity of every access token.
- Follow best practices for internal and external use. The source gives JSON Web Tokens with the parenthetical “internal only”; preserve that restriction/example without generalizing it beyond the wording.
- Apply encryption under SAK Cryptografie Management.

## Dependencies and source limitations

| Dependency | Use for |
|---|---|
| Identity & Access Management | Identities/access through interface layers |
| Security Monitoring | End-to-end access logging, SOC use cases |
| Cryptografie Management | Encryption and cryptographic controls |
| Isolatie / Network Security | Technical embedding, data diode, secure file transfer |
| Disaster Recovery | Emergency scenarios |
| Vulnerability Management / Content Security Management | Security-device functions and content scanning |
| RWS zoning, network architecture, CSIR, MK policy | Zone assignments and detailed architecture |

- Coverage: substantive source §§1–4.4, all 11 controls, the full §1.6 table, and the page-5 architecture illustration's material legend/context. Cover, colophon, version history, contents, and decorative capability diagrams are omitted.
- The scope table's 11 rows, 15 populated cells, 40 blanks, headers, orientation, and domain colors were visually checked against PDF page 7. The blank cells remain uninterpreted.
- Material source defects/ambiguities: §1.1 says there are **four** goals but visibly presents only **three**; §§4.1 and 4.2 duplicate their fields/review interval; §2.3's unidirectional Beheer-to-MK rule blocks return traffic even though the rationale uses “reachable,” so do not invent a bidirectional exception; the source provides no availability/scale thresholds; and the JWT “internal only” wording in §4.4 is terse.
- Original input Markdown SHA-256, before the transcription note: `7e1885eb1c60308ecbbf2b1cf49db2e4cd1ca3eaa75afbebacbba5fb14c842d5`.
- Source PDF SHA-256: `6d293de038d562f996fb08be68540267cb26dcdf3d2001516c2ab350d691afc5`.