ArchyRWS architecture
Menu
Archy RWS architecture
Markdown is the sourceBackend considerations
Search Archy…

Search Archy

SAK MK-werkplekken — distilled rules (English)

CurrentRWS BEDRIJFSVERTROUWELIJKReview not recorded

The author presents this as the current position. It is not a record of approval.

Local drafting workspace

SAK MK-werkplekken — distilled rules (English)

Security/SAK/SAK - MK-werkplekken v1.0.distilled.en.md

Local draft — not saved or submitted. Download and use the Git/PR workflow. Changes stay in this page’s memory, never alter the published note, and are lost on reload. The .md download contains the narrative only; preserve the original frontmatter in Git. The preview is not publication validation.

Preview

Images and raw HTML are disabled. Preview links do not navigate. Markdown links are checked when the source is built, not here.

Published source loaded. No local changes.

View source & provenance

Classification: RWS BEDRIJFSVERTROUWELIJK.

Source: SAK - MK-werkplekken v1.0.pdf, version 1.0, 28 July 2025, status DEFINITIEF. Derived from the Docling Markdown, with visually checked scope table. The issued PDF contains 13 pages.

This is a non-authoritative English distillation. All § references refer to the source PDF. SAK MKW A–C are source control groups. Bullets condense source requirements and activities; they are not new official IDs. The issued Dutch source governs. Safety/security exceptions and “where possible” qualifications are preserved.

How to apply

  • Apply this SAK to mission-critical workplaces in the Mission-Critical Chain (MKK): IA object-operator workplaces, mission-critical IV workplaces needed to support IA operation, and Purdue levels 2 and 3 (§§1–1.1, PDF page 5).
  • All §1.7 control rows apply only in the Workplace domain, marked IV/IA; other domain cells are blank. Blank cells are unspecified, not proof that dependencies in other domains are irrelevant.
  • Apply the safety and operational-continuity principles before selecting ordinary office-workplace controls. Security may yield in specific cases where an essential function is at stake, but resulting cyber risk must be mitigated with compensating measures (§§1.3 and 2, PDF pages 6 and 8).
  • Distinguish the primary operator workplace, maintenance operation, emergency operation, and local operation. Requirements differ by function and fallback role.
  • Preserve explicit exceptions: internet/email or external media are allowed only where necessary for the primary function (and, for media, antivirus scanning); legacy compensating measures and anomaly monitoring are qualified by feasibility.
  • For a finding, cite SAK - MK-werkplekken v1.0.pdf — SAK MKW <group>, §<section> and add the PDF page where useful.

Terms

  • MK workplace: mainly an IA workplace used to operate or control an object, centrally or locally; it can also be an IV workplace essential to continued operation/control (§1, PDF page 5).
  • KA workplace: a standard office-automation workplace, contrasted with an MK workplace.
  • Essential functions: include, but are not limited to, the safety-instrumented function, control function, and the operator's ability to view and operate controlled equipment (§2, citing ANSI/ISA-62443-3-3 in the source).
  • EOL / legacy: a product, system, or software item no longer supported by its manufacturer (§1 footnote).
  • Fail safe: fallback to a defined safe state when normal operation fails. Deterministic output: the same output for the same input, supporting predictability and reliability (§2.4 footnote).
  • Degraded mode: reduced-capacity operation preserving essential functions during faults (§3.3 footnote).
  • CSLM: the source's specialized IA monitoring sensor/agent capability; detailed sensor requirements are delegated to SAK Security Monitoring.

Applicability index — source §1.7, PDF page 7

Controls Datacenter Network Application Workplace Cloud
§§2.1–2.6, 3.1–3.5, 4.1 — — — IV/IA —

The PDF uses different colors for the five domain columns but supplies no semantic legend; applicability comes from the cell text. The workplace column is light green and contains every populated cell.

Cross-cutting MK-workplace rules — §§1–1.3

When: designing, operating, or assessing a workplace needed for mission-critical IA control or operation.

  • Provide safety procedures that guarantee workplace integrity and availability.
  • Design each MK workplace for a specific primary task within the IA object and use it only for that purpose.
  • Do not let cybersecurity controls impede the workplace's primary task. Mitigate resulting cyber risks with compensating measures.
  • On failure, make the workplace return to a safe state (Safety First).
  • Keep operation/control continuously available so the primary function can be performed.
  • Integrate MK workplaces with legacy systems securely.
  • Account for regular communication with EOL operational machines that may be irreplaceable and no longer receive vendor security updates.

The zoning diagram on PDF page 5 provides architecture context across Purdue zones and RWS security zones, including firewalls, sensors, interfaces, management, SOC/NOC, office workplaces, internet, and cloud. It is not a traffic-permission matrix and does not by itself grant connectivity.

SAK MKW A — Safety of people and equipment/environment

§2.1 — Safety procedures

When: establishing the overall control set for an MK workplace.

The workplace must:

  1. Meet the secure-access procedures in §2.2.
  2. Meet the additional security principles intended by the source; its cross-reference is broken (Fout! Verwijzingsbron niet gevonden.), while the named section is §2.3.
  3. Be excepted from specified principles used for standard KA workplaces under §2.4.
  4. Meet integrity requirements. The source cites §2.4, although the titled integrity section is §2.5; do not silently resolve this numbering conflict in a formal finding.
  5. Meet availability requirements in §3.2.

§2.2 — Secure-access procedures

When: granting physical or logical access to an MK workplace.

  • Grant access only after successful authentication and authorization.
  • Use role-based access applying need to have and segregation of duties.
  • Physical access to the MK workplace occurs at the operator workplace.
  • Require local logical access to be requested from and approved by the responsible, mandated line manager.
  • Require at least:
    • Local operation: user ID and password.
    • Local administration and administrator accounts: two-factor authentication using possession plus knowledge.
    • Remote administration and maintenance: two-factor authentication and access only through the central secured facilities.

These are minimum/source-specific access requirements; the broader IAM and Remote Access SAKs may add constraints.

§2.3 — Additional security principles

When: configuring and using an MK workplace rather than a standard KA workplace.

  1. Use the workplace only for its configured primary task.
  2. Install only software that (1) is needed to perform the primary task and (2) supports continuation of the primary task. The source joins these conditions with “and”; do not treat general productivity software as implicitly allowed.
  3. Use uniform operating procedures and applications so staff can work across different workplaces and take over each other's tasks.
  4. Operation should not require specific knowledge or expertise of the underlying IA object; preserve this source formulation rather than strengthening it into a claim that no training is needed.
  5. Permit no internet access or email, unless necessary for the primary function.
  6. Separate MK workplaces from standard KA workplaces both logically and physically: use a separate network and do not place them in the same room.
  7. Show operators only fault messages concerning functional impact, using terms suited to functional system use. Route technical fault messages to the administration/maintenance domain.
  8. Prevent connection of external systems or media such as USB drives, unless required for the primary function or antivirus scanning under SAK Endpoint Security.
  9. Restrict and closely control system utilities capable of bypassing MK-workplace security controls. Permit only authorized personnel, log use, and retain the logs for at least six months.

§2.4 — Deviating security principles

When: standard KA-workplace controls could obstruct an essential function or emergency operation.

  • On failure, return the MK workplace to a defined fail-safe state, unlike the fail-secure principle stated for KA workplaces. Define the deterministic output used when normal operation fails.
  • Limit security measures such as real-time antivirus scanning when they would impede the primary task.
  • Allow operators to switch workplaces when needed to operate an object.
  • Do not automatically lock the screen or session. Lock/termination may occur only upon manual logout or removal of the chip-card token. Do not use screen savers.

Boundary: these exceptions protect operational safety and continuity; they do not remove the requirement to mitigate cyber risk with compensating measures.

§2.5 — System-integrity requirements

When: defining or validating reliable MK-workplace operation.

  • Communication integrity: unauthorized users must not manipulate system-to-system communication.
  • Software/information integrity: unauthorized users must not manipulate software or information on systems.
  • Session integrity: unauthorized users must not misuse or manipulate workplace sessions.
  • Input validation: validate entered input against system-defined criteria.
  • Error handling: respond safely to system errors.

§2.6 — Verification and validation system

When: continuously establishing whether the workplace remains reliable and operational.

The system must:

  1. Check compliance with §2.5 integrity requirements.
  2. Check compliance with §3.2 availability requirements.
  3. Check that all defined workplace security measures are active.
  4. Perform a control/check for every action executed on the workplace.

The source does not define the mechanism, performance boundary, or exception to the every-action requirement. Do not weaken it silently, but assess implementation against the primary-task non-impediment principle.

SAK MKW B — Operational continuity

§3.1 — Availability procedures

When: protecting workplaces against outage, faults, cyberattack, or emergency conditions.

  • Provide a DoS protection system under §3.3 so the workplace is not overloaded.
  • Monitor MK workplaces with a specialized IA monitoring system to detect failing or abnormal systems in time. The source cross-reference is broken; §3.5 defines the CSLM agent and points to SAK Security Monitoring for the sensor.
  • Primarily control objects from the central operator MK workplace.
  • If the primary workplace is unavailable, switch to one of these alternative consoles:
    1. Maintenance operation.
    2. Emergency operation under §3.4; the source prints the malformed reference 3.43.4.
    3. Local operation.
  • Also apply SAK Business Continuity Management and Disaster Recovery.

§3.2 — Availability requirements

When: operating any in-scope MK workplace.

  • Make it available 24/7 for operational use.
  • Keep it operational in isolation.
  • Make it independent of internet and cloud services.
  • Make it independent of normal power by connecting it to emergency power.

§3.3 — Denial-of-Service protection system

When: protecting the workplace against high network-traffic load or user-caused DoS events.

The system must:

  1. Limit users' ability to cause DoS events.
  2. Switch the workplace to degraded mode under high network-traffic load.
  3. Apply rate limiting so the workplace can withstand the traffic.

§3.4 — Emergency operation

When: the primary operation facility fails.

  • Provide an emergency-operation facility to which operation can switch.
  • Give it the same operating capabilities as primary operation.
  • Allow it to run in degraded mode to prevent overload.
  • Test and check it periodically; no numeric frequency is specified.
  • Make it independent of primary operation.
  • Use a different operating system than primary operation so primary faults do not propagate. “Operating system” here translates the source's bedieningssysteem and may mean the operational control system rather than a commodity OS; clarify in design context.
  • If emergency operation is unavailable, use local operation.

§3.5 — CSLM agent

When: monitoring MK-workplace traffic flows and internal IA processes.

  • Run the agent actively on all MK workplaces to map all data flows.
  • Integrate it with the CSLM sensor under SAK Security Monitoring.
  • Collect data about anomalous IA-domain flows and specific IA protocols.
  • Use a SOC interface to forward data to the RWS SOC.
  • Ensure agent failure has no effect on MK-workplace operation.

SAK MKW C — Secure legacy-system integration

§4.1 — Safe support of legacy systems

When: an MK workplace communicates with an EOL or otherwise unsupported legacy system.

  • If internet connectivity is necessary for the workplace's function, do not place that workplace in the same network as legacy systems.
  • Do not permit direct remote login from MK workplaces to legacy systems. Permit it only through appropriate security measures, such as a stepping stone or the controlled third-party-access route.
  • Apply compensating measures where possible to mitigate legacy-system vulnerabilities.
  • Strictly monitor traffic between MK workplaces and legacy systems for deviations where possible. Treat anomalies as possible indicators of attempted abuse, including malicious code.

Referenced controls outside this document

Dependency Consult for
SAK Endpoint Security Antivirus/EDR and controlled media scanning on MK workplaces
SAK Security Monitoring Security-event monitoring, CSLM sensor, SOC integration
SAK Vulnerability Management Managing MK-workplace and legacy vulnerabilities
SAK MK-koppelvlakken Secure connections between workplaces and IA components
SAK Technical Compliance Management Continuous compliance with baselines and RWS frameworks
SAK Identity & Access Management Authentication, authorization, roles, and segregation of duties
SAK Remote Access Management / controlled third-party access Central secured remote administration and legacy-access route
SAK Business Continuity Management and Disaster Recovery Alternative operation and recovery arrangements
RWS IA principles, modular technical architecture, LBS, and LTS Detailed operational architecture and applicable object standards

Extraction and verification limits

  • The distillation covers substantive prose and controls §§1–4.1, including definitions in footnotes and the normative availability/access exceptions. Cover, colophon, authors, version history, contents, generic SAK-positioning prose, and decorative images are omitted.
  • The §1.7 scope table's 12 rows, five domain columns, orientation, populated/blank cells, and domain-color pattern were visually checked against PDF page 7. Values already matched; a separate transcription note was added to the original Markdown. No other substantive policy table appears in the body.
  • The architecture image on PDF page 5 was inspected for context, but it is not reproduced as a rule table and was not used to infer permissions or requirements absent from prose.
  • Material source defects retained: broken/misdirected references in §§2.1 and 3.1; the incomplete quotation/punctuation in §2.2(c); tension between every-action verification and non-impediment of the primary task; undefined frequencies for periodic emergency-operation tests; and feasibility qualifications for legacy controls. These are not silently repaired as policy.
  • Original input Markdown SHA-256, before repair: 673786093074f2bd3a9011b7da56b2d884c98a1e60b021f1c15e232c25c31442.
  • Source PDF SHA-256: 2b430734992f4d7ef48b5cd8df95d8996376d00ec243a61f164331c521f24a4c.
Explore this note’s relationships 2 connected notes

Connections are authored references and declared relationships, not verified runtime dependencies or approval.

3 notes · 2 relationships

Every note and relationship is available in the list below. The interactive map requires JavaScript.

Outline is the note kindABBSBBHLDResearchNoteMarkdown referenceTyped relationship
Icon is the documented subjectGeneral note
Notes and relationships Accessible list

Notes (3)

Relationships (2)

Source & provenance

This is the published reading view. The Markdown source and Git review workflow remain authoritative; publication is not architectural approval.

Source
Security/SAK/SAK - MK-werkplekken v1.0.distilled.en.md
Kind
Note
Status
Current, as authored
Classification
RWS BEDRIJFSVERTROUWELIJK
Revision
a3203210221340f80866b0462f4d63b49ebc5aea

Review not recorded. A recorded review date is the author’s review of the whole note, not an edit date, build date or approval. Editing a local draft does not update it.

Read the Markdown source

Read-only narrative source. Authored labels and relationships are listed above; this view does not write to the vault.


# SAK MK-werkplekken — distilled rules (English)

**Classification: RWS BEDRIJFSVERTROUWELIJK.**

**Source:** SAK - MK-werkplekken v1.0.pdf, version 1.0, 28 July 2025, status DEFINITIEF. Derived from [the Docling Markdown, with visually checked scope table](SAK%20-%20MK-werkplekken%20v1.0.md). The issued PDF contains 13 pages.

This is a non-authoritative English distillation. All `§` references refer to the source PDF. `SAK MKW A–C` are source control groups. Bullets condense source requirements and activities; they are not new official IDs. The issued Dutch source governs. Safety/security exceptions and “where possible” qualifications are preserved.

## How to apply

- Apply this SAK to mission-critical workplaces in the Mission-Critical Chain (**MKK**): IA object-operator workplaces, mission-critical IV workplaces needed to support IA operation, and Purdue levels **2 and 3** (§§1–1.1, PDF page 5).
- All §1.7 control rows apply only in the **Workplace** domain, marked `IV/IA`; other domain cells are blank. Blank cells are unspecified, not proof that dependencies in other domains are irrelevant.
- Apply the safety and operational-continuity principles before selecting ordinary office-workplace controls. Security may yield in specific cases where an **essential function** is at stake, but resulting cyber risk must be mitigated with compensating measures (§§1.3 and 2, PDF pages 6 and 8).
- Distinguish the primary operator workplace, maintenance operation, emergency operation, and local operation. Requirements differ by function and fallback role.
- Preserve explicit exceptions: internet/email or external media are allowed only where necessary for the primary function (and, for media, antivirus scanning); legacy compensating measures and anomaly monitoring are qualified by feasibility.
- For a finding, cite `SAK - MK-werkplekken v1.0.pdf — SAK MKW <group>, §<section>` and add the PDF page where useful.

### Terms

- **MK workplace:** mainly an IA workplace used to operate or control an object, centrally or locally; it can also be an IV workplace essential to continued operation/control (§1, PDF page 5).
- **KA workplace:** a standard office-automation workplace, contrasted with an MK workplace.
- **Essential functions:** include, but are not limited to, the safety-instrumented function, control function, and the operator's ability to view and operate controlled equipment (§2, citing ANSI/ISA-62443-3-3 in the source).
- **EOL / legacy:** a product, system, or software item no longer supported by its manufacturer (§1 footnote).
- **Fail safe:** fallback to a defined safe state when normal operation fails. **Deterministic output:** the same output for the same input, supporting predictability and reliability (§2.4 footnote).
- **Degraded mode:** reduced-capacity operation preserving essential functions during faults (§3.3 footnote).
- **CSLM:** the source's specialized IA monitoring sensor/agent capability; detailed sensor requirements are delegated to SAK Security Monitoring.

## Applicability index — source §1.7, PDF page 7

| Controls | Datacenter | Network | Application | Workplace | Cloud |
|---|---|---|---|---|---|
| §§2.1–2.6, 3.1–3.5, 4.1 | — | — | — | IV/IA | — |

The PDF uses different colors for the five domain columns but supplies no semantic legend; applicability comes from the cell text. The workplace column is light green and contains every populated cell.

## Cross-cutting MK-workplace rules — §§1–1.3

**When:** designing, operating, or assessing a workplace needed for mission-critical IA control or operation.

- Provide safety procedures that guarantee workplace integrity and availability.
- Design each MK workplace for a specific primary task within the IA object and use it only for that purpose.
- Do not let cybersecurity controls impede the workplace's primary task. Mitigate resulting cyber risks with compensating measures.
- On failure, make the workplace return to a safe state (**Safety First**).
- Keep operation/control continuously available so the primary function can be performed.
- Integrate MK workplaces with legacy systems securely.
- Account for regular communication with EOL operational machines that may be irreplaceable and no longer receive vendor security updates.

The zoning diagram on PDF page 5 provides architecture context across Purdue zones and RWS security zones, including firewalls, sensors, interfaces, management, SOC/NOC, office workplaces, internet, and cloud. It is not a traffic-permission matrix and does not by itself grant connectivity.

## SAK MKW A — Safety of people and equipment/environment

### §2.1 — Safety procedures

**When:** establishing the overall control set for an MK workplace.

The workplace must:

1. Meet the secure-access procedures in §2.2.
2. Meet the additional security principles intended by the source; its cross-reference is broken (`Fout! Verwijzingsbron niet gevonden.`), while the named section is §2.3.
3. Be excepted from specified principles used for standard KA workplaces under §2.4.
4. Meet integrity requirements. The source cites §2.4, although the titled integrity section is §2.5; do not silently resolve this numbering conflict in a formal finding.
5. Meet availability requirements in §3.2.

### §2.2 — Secure-access procedures

**When:** granting physical or logical access to an MK workplace.

- Grant access only after successful authentication and authorization.
- Use role-based access applying **need to have** and **segregation of duties**.
- Physical access to the MK workplace occurs at the operator workplace.
- Require local logical access to be requested from and approved by the responsible, mandated line manager.
- Require at least:
  - **Local operation:** user ID and password.
  - **Local administration and administrator accounts:** two-factor authentication using possession plus knowledge.
  - **Remote administration and maintenance:** two-factor authentication and access only through the central secured facilities.

These are minimum/source-specific access requirements; the broader IAM and Remote Access SAKs may add constraints.

### §2.3 — Additional security principles

**When:** configuring and using an MK workplace rather than a standard KA workplace.

1. Use the workplace only for its configured primary task.
2. Install only software that **(1) is needed to perform the primary task and (2) supports continuation of the primary task**. The source joins these conditions with “and”; do not treat general productivity software as implicitly allowed.
3. Use uniform operating procedures and applications so staff can work across different workplaces and take over each other's tasks.
4. Operation **should not require specific knowledge or expertise of the underlying IA object**; preserve this source formulation rather than strengthening it into a claim that no training is needed.
5. Permit no internet access or email, **unless necessary for the primary function**.
6. Separate MK workplaces from standard KA workplaces both logically and physically: use a separate network and do not place them in the same room.
7. Show operators only fault messages concerning functional impact, using terms suited to functional system use. Route technical fault messages to the administration/maintenance domain.
8. Prevent connection of external systems or media such as USB drives, **unless required for the primary function or antivirus scanning** under SAK Endpoint Security.
9. Restrict and closely control system utilities capable of bypassing MK-workplace security controls. Permit only authorized personnel, log use, and retain the logs for **at least six months**.

### §2.4 — Deviating security principles

**When:** standard KA-workplace controls could obstruct an essential function or emergency operation.

- On failure, return the MK workplace to a defined **fail-safe** state, unlike the fail-secure principle stated for KA workplaces. Define the deterministic output used when normal operation fails.
- Limit security measures such as real-time antivirus scanning when they would impede the primary task.
- Allow operators to switch workplaces when needed to operate an object.
- Do **not** automatically lock the screen or session. Lock/termination may occur only upon manual logout or removal of the chip-card token. Do not use screen savers.

**Boundary:** these exceptions protect operational safety and continuity; they do not remove the requirement to mitigate cyber risk with compensating measures.

### §2.5 — System-integrity requirements

**When:** defining or validating reliable MK-workplace operation.

- **Communication integrity:** unauthorized users must not manipulate system-to-system communication.
- **Software/information integrity:** unauthorized users must not manipulate software or information on systems.
- **Session integrity:** unauthorized users must not misuse or manipulate workplace sessions.
- **Input validation:** validate entered input against system-defined criteria.
- **Error handling:** respond safely to system errors.

### §2.6 — Verification and validation system

**When:** continuously establishing whether the workplace remains reliable and operational.

The system must:

1. Check compliance with §2.5 integrity requirements.
2. Check compliance with §3.2 availability requirements.
3. Check that all defined workplace security measures are active.
4. Perform a control/check **for every action executed on the workplace**.

The source does not define the mechanism, performance boundary, or exception to the every-action requirement. Do not weaken it silently, but assess implementation against the primary-task non-impediment principle.

## SAK MKW B — Operational continuity

### §3.1 — Availability procedures

**When:** protecting workplaces against outage, faults, cyberattack, or emergency conditions.

- Provide a DoS protection system under §3.3 so the workplace is not overloaded.
- Monitor MK workplaces with a specialized IA monitoring system to detect failing or abnormal systems in time. The source cross-reference is broken; §3.5 defines the CSLM agent and points to SAK Security Monitoring for the sensor.
- Primarily control objects from the central operator MK workplace.
- If the primary workplace is unavailable, switch to one of these alternative consoles:
  1. Maintenance operation.
  2. Emergency operation under §3.4; the source prints the malformed reference `3.43.4`.
  3. Local operation.
- Also apply SAK Business Continuity Management and Disaster Recovery.

### §3.2 — Availability requirements

**When:** operating any in-scope MK workplace.

- Make it available **24/7** for operational use.
- Keep it operational in isolation.
- Make it independent of internet and cloud services.
- Make it independent of normal power by connecting it to emergency power.

### §3.3 — Denial-of-Service protection system

**When:** protecting the workplace against high network-traffic load or user-caused DoS events.

The system must:

1. Limit users' ability to cause DoS events.
2. Switch the workplace to degraded mode under high network-traffic load.
3. Apply rate limiting so the workplace can withstand the traffic.

### §3.4 — Emergency operation

**When:** the primary operation facility fails.

- Provide an emergency-operation facility to which operation can switch.
- Give it the same operating capabilities as primary operation.
- Allow it to run in degraded mode to prevent overload.
- Test and check it **periodically**; no numeric frequency is specified.
- Make it independent of primary operation.
- Use a different operating system than primary operation so primary faults do not propagate. “Operating system” here translates the source's `bedieningssysteem` and may mean the operational control system rather than a commodity OS; clarify in design context.
- If emergency operation is unavailable, use local operation.

### §3.5 — CSLM agent

**When:** monitoring MK-workplace traffic flows and internal IA processes.

- Run the agent actively on **all MK workplaces** to map all data flows.
- Integrate it with the CSLM sensor under SAK Security Monitoring.
- Collect data about anomalous IA-domain flows and specific IA protocols.
- Use a SOC interface to forward data to the RWS SOC.
- Ensure agent failure has **no effect** on MK-workplace operation.

## SAK MKW C — Secure legacy-system integration

### §4.1 — Safe support of legacy systems

**When:** an MK workplace communicates with an EOL or otherwise unsupported legacy system.

- If internet connectivity is necessary for the workplace's function, do not place that workplace in the same network as legacy systems.
- Do not permit direct remote login from MK workplaces to legacy systems. Permit it only through appropriate security measures, such as a stepping stone or the controlled third-party-access route.
- Apply compensating measures **where possible** to mitigate legacy-system vulnerabilities.
- Strictly monitor traffic between MK workplaces and legacy systems for deviations **where possible**. Treat anomalies as possible indicators of attempted abuse, including malicious code.

## Referenced controls outside this document

| Dependency | Consult for |
|---|---|
| SAK Endpoint Security | Antivirus/EDR and controlled media scanning on MK workplaces |
| SAK Security Monitoring | Security-event monitoring, CSLM sensor, SOC integration |
| SAK Vulnerability Management | Managing MK-workplace and legacy vulnerabilities |
| SAK MK-koppelvlakken | Secure connections between workplaces and IA components |
| SAK Technical Compliance Management | Continuous compliance with baselines and RWS frameworks |
| SAK Identity & Access Management | Authentication, authorization, roles, and segregation of duties |
| SAK Remote Access Management / controlled third-party access | Central secured remote administration and legacy-access route |
| SAK Business Continuity Management and Disaster Recovery | Alternative operation and recovery arrangements |
| RWS IA principles, modular technical architecture, LBS, and LTS | Detailed operational architecture and applicable object standards |

## Extraction and verification limits

- The distillation covers substantive prose and controls §§1–4.1, including definitions in footnotes and the normative availability/access exceptions. Cover, colophon, authors, version history, contents, generic SAK-positioning prose, and decorative images are omitted.
- The §1.7 scope table's 12 rows, five domain columns, orientation, populated/blank cells, and domain-color pattern were visually checked against PDF page 7. Values already matched; a separate transcription note was added to the original Markdown. No other substantive policy table appears in the body.
- The architecture image on PDF page 5 was inspected for context, but it is not reproduced as a rule table and was not used to infer permissions or requirements absent from prose.
- Material source defects retained: broken/misdirected references in §§2.1 and 3.1; the incomplete quotation/punctuation in §2.2(c); tension between every-action verification and non-impediment of the primary task; undefined frequencies for periodic emergency-operation tests; and feasibility qualifications for legacy controls. These are not silently repaired as policy.
- Original input Markdown SHA-256, before repair: `673786093074f2bd3a9011b7da56b2d884c98a1e60b021f1c15e232c25c31442`.
- Source PDF SHA-256: `2b430734992f4d7ef48b5cd8df95d8996376d00ec243a61f164331c521f24a4c`.